Illegal Installation
The conduit used in this installation is not designed for direct-burial or outdoor use. In addition, for this application, Table 300.5 of the National Electrical Code (NEC) specifies a minimum burial depth of 18"; this flexible metal conduit (FMC) was buried just a few inches below grade.

undersized wiring
This installation did not undergo inspection; it was installed by someone unqualified. Wire gauge was too small for the load and the conduit was not properly terminated at the electrical enclosure.

Incorrect Conduit
The conduit used in this installation is not designed for direct-burial or outdoor use. In addition, for this application, Table 300.5 of the National Electrical Code (NEC) specifies a minimum burial depth of 18"; this flexible metal conduit (FMC) was buried just a few inches below grade.

Correct Conduit
Conduit appropriate for direct burial is now installed; it is buried to a depth of 18", which meets minimum code requirements.

Proper Anchorage
The conduit is now appropriate for direct-burial; it is properly anchored and terminated at the electrical disconnect switch.

Corrected Wiring
The wiring size and color now match that specified by the equipment manufacturer. The wiring is encased in appropriate rigid PVC conduit that is properly anchored and terminated at the electrical enclosure.

Area Restoration
Here, ORMECO technicians are placing landscape stones and gravel over the work area, restoring the area to its original condition.