Hot Tubs

We can service most brands of hot tubs. This HotSpring brand was out-of-service for nearly two years; it leaked and the heater did not work. For this repair, the leaking heater elements and other components were replaced. Electricians replaced the underground electrical feeders; these were not installed correctly and did not meet minimum code.

 

water chemistry

ORMECO can test your pool or SPA water for pH, total alkalinity, hardness, and free chlorine. Give us a call today!

IMG_2241
Original COndition

Because of a failed heater and leaks, this hot tub sat unused for nearly two years.  In that time the cover deteriorated and rainwater, bugs, and debris collected in the basin.

IMG_2265
cleanup

The tub was drained, cleaned, and sanitized.  New filters were installed and a new cover ordered.

IMG_2240
Unsafe Electrical

Electrical feeders were encased inside buried flexible metal conduit (FMC). This illegal installation violated minimum code and created a very dangerous electrocution hazard.  In addition, the FMC was not properly terminated inside the enclosure (circled in red).

IMG_2254
Failed Heater

The heater had failed and was leaking; it was replaced with a new and updated 6 kW type.

IMG_2528
Hazardous Electrical

The wrong type of underground conduit was used.  In addition, it was buried just beneath the surface.

IMG_2578
New Electrical

Minimum code requires 18" burial depth.  New watertight, rigid polyvinyl chloride (PVC) electrical conduit was installed below grade.

IMG_2582
Electrical Disconnect

Conduit was anchored to the structure and new wires were pulled between the disconnect and hot tub.

IMG_2592
Cleanup

Here, pea gravel and concrete pavers are being placed around the hot tub.

IMG_2583
Electrical Terminations

Feeders from the disconnect panel are now properly terminated inside the hot tub electrical enclosure.  Wire gauge and color now matches that specified by the hot tub manufacturer.

IMG_2683
Repairing Leaks

Hot tub leaks in some brands are extremely difficult to locate. The pipe and tubing in this 400 gallon HotSpring tub is completed entombed in expansion foam, which must be painstakingly removed. This tub was leaking at roughly 4 gallons/hour.  Within 4 days it was virtually empty. A cracked drain tube was responsible for the leak.

IMG_2697
Refoam

Once the leak was repaired, the underside of the tub was re-insulated and sealed with expansion foam.

IMG_2711
Shaping and trim

The cured foam was then shaped and smoothed to match the contours of the outer covers.

IMG_2703
vapor barrier

A vapor barrier covered the original foam insulation. To maintain a professional factory appearance, this barrier was replaced.

IMG_2712
Finished Repair

The vapor barrier, being paper, can help identify the location of any future leaks.  Mold and wet paper was how the general area of the original leak was determined.

IMG_2714
Like New Appearance

With the outer skins installed, this hot tub is ready for use. There was much wrong with this tub, but the repair cost was still far less less than replacement.

Next Steps...

If you are having hot tub problems, give us a call today!